Fume Extraction System

FUME-EXTRACTION-SYSTEMS_31.jpg  
   
A healthy, safe working environment is an essential requirement for an effective and productive workplace. This applies to any workplace, but perhaps even more specifically to the laboratory. For this reason Fume Extraction Systems are needed where dangerous gases, fumes, aerosol propellants or dust particles can escape during working processes.  

LabPlus offers a wide range of products to meet the fume containment needs. With innovative design and construction, these units assure the maximum safety and performance for the end user.

.............................................................................................................................................................

Worktops.jpg
Cabinetry.jpg
Fume-Extration.jpg
Service-Fittings.jpg
Safety-System.jpg
Special-Storage.jpg
Accessories.jpg
Special-Benches1.jpg
Reception-Counters.jpg
Shelving-System.jpg

Auxilliary Air Inlet System

Auxiliary air in-let system is supplied (optional) where the laboratories are small or the number of extraction systems are more. In this case an auxiliary air supply from outside the laboratory is given to satisfy almost 75% of the needed volume. This helps to save cost and energy in air conditioning.

.............................................................................................................................................................

By-pass System

By-pass system is also provided (optional) to reduce the face velocity when the front sash is closed, thus preventing high variation in face velocity and disturbing turbulence.

.............................................................................................................................................................

Airflow Monitoring System

A security device, which monitors the volume of airflow and gives audible alarm and flashing red light in case the airflow drops from a prefixed volume/hr. The extraction systems are selected considering the requirements of the laboratory. Extraction systems with a capacity of 450 - 1600 m3 /hr are provided, depending on the application and size of fume cupboard. Centrifugal extractor fans are available. The fume cupboard worktop shall be manufactured with selected material such as Epoxy, Ceramic Tile, Stainless Steel etc. according to the demands of application. The depth of the worktop is 750mm and the width shall be 900mm, 1200mm, 1500mm, 1800mm, etc. The standard overall dimension of a fume cupboard is 900mm deep and 2400mm high and the width shall be of 940mm, 1240mm, 1540mm, 1840mm etc.

.............................................................................................................................................................

Bench Mounted Fume Hood

Bench mounted Fume Hoods are constructed same as the fume cupboard, without the frames and under bench cabinets. The service box is fixed under the existing worktop and the Fume Hood is placed above the worktop. The fume chamber design is similar to the fume cupboard. Sleek models are available on request for accommodating on narrow benches. Like Fume Cupboard, Fume Hood is also supplied with suitable fan to fit the application.The standard sizes are 940mm, 1240mm, 1500mm and 1800mm.

.............................................................................................................................................................

Canopy Hood

Canopy Hoods are used where closed workspace is not essential. By providing Canopy Hood at the top, accesses to the sides are made easy. Manufactured with Stainless Steel or Epoxy coated mild steel. Wall mounted and hanging units are supplied depending on the position and site conditions. Canopy hoods are also supplied with the extraction unit of different capacities to suit the requirement. Canopy hoods can be manufactured in any size to suit the application.

.............................................................................................................................................................

Flexible Suction Arms

Fume Extraction Arms are used in places where the minimum extraction volume is required within a limited area.LabPlus offers a wide range of Fume Extraction Arms in different sizes made of Stainless Steel or Flexible plastic tubes. The standard sizes available are 25mm, 32mm, 38mm and 54mm diameter. The extraction volume varies from 25m3/hr to 100m3/hr. Special sizes and capacities can be supplied on request.
.............................................................................................................................................................

 